A hard reset is performed when a SCRAM CAM or House Arrest Bracelet will not successfully communicate with SCRAMNET®. This page describes the steps that MUST be followed in order to reset the status (or state) of a bracelet.
What you will need:
- Direct Connect device with USB cable
- New faceplate and battery
- Magnet
Procedure
- Preliminary Steps
- Re-initialize the bracelet.
- In SCRAMNET, access the client’s Equipment page.
- Click the Maintenance link.
- Select the Battery, Faceplate and Exhaust Cap Replaced check box.
- Click the Finish button.
The re-initialization will begin when the hard reset process is complete.
- Open the Direct Connect application.
- Remove the bracelet.
- Remove the bracelet faceplate and battery.
- Re-initialize the bracelet.
- Perform Hard Reset
- Attach the Direct Connect device to the bracelet and connect the USB cable between the device and your computer.
- Place the magnet on the Direct Connect device where the word “magnet” appears.
- After 30 seconds, with the magnet still held on the device, install a new battery.
- Immediately remove the magnet.
- On the Direct Connect device, the red light turns off while the blue light remains on.
- When both lights on the Direct Connect device turn back on and the status on the Direct Connect application displays “Communication Complete”, remove the device from the bracelet.
- Final Steps
- Install a new faceplate.
- Attach the bracelet.
- Verify that the re-initialization has started:
- In SCRAMNET, access the client’s Reports page.
- Click the Communication sub-tab.
- Verify by looking at the top Date/Time link that SCRAMNET has received bracelet readings.
- Open the communication and verify that a “Bracelet Started Initialization” message appears.
- Wake up the bracelet to ensure that the pump runs.
- Install the tamper clips.